22/07/2019

On 11 March 2017, contrary to crew expectations based on their pre-flight takeoff performance calculation, an Airbus 340-300 taking off from the 3,800 metre-long at Bogata only became airborne just before the end of the runway. The Investigation found that the immediate reason for this was the inadequate rate of rotation achieved by the Training Captain performing the takeoff. However, it was also found that the operator's average A340-300 rotation rate was less than would be achieved using handling recommendations which themselves would not achieve the expected performance produced by the Airbus takeoff performance software that reflected type certification findings.